Price
Estimated deliver 5-7 days
People are viewing this right now
Brand Name: BOGUANG
Origin: Mainland China
Number of Panels: >20
Flexible Solar Panel: Yes
Foldable Solar Panel: No
Hign-concerned Chemical: None
Type: Solar Panel
Module Efficien: 24%
Model Number: Solar Panel
Size: 975*550*3mm
Material: Monocrystalline Silicon
Nominal Capacity: 100W / 200W / 300W / 400W / 500W /1000W
Number of Cells: 30 pcs solar cell
Max. Power: 100W / 200W / 300W / 400W / 500W /1000W
is_customized: Yes
Certification: CE
Certification: FCC
Certification: weee
100 watt - 1000W Portable 12v solar panel complete kit 12 volt battery charger Motorhome Camping flexible solar plate cell energy Outdoor photovoltaic stations solar panels system 12V to 110V / 220V (100w / 200W/ 300W/400W/500W/1000W)
1pcs 100w Packing listing
1pcs 100w flexible solar panel
2pcx 100W Packing listing
2pcs 100w flexible solar panel
3pcx 100W Packing listing
3pcs 100w flexible solar panel
4pcx 100W Packing listing
4pcs 100w flexible solar panel
5pcx 100W Packing listing
5pcs 100w flexible solar panel
10pcx 100W Packing listing
10pcs 100w flexible solar panel
12V 100W kit Packing listing
1x100W Solar Panels
1 Set 1.5m cable with PV plug
1 Set 3m cable with crocodile clamp
1 x 10A controller
200W kit Packing listing
2x100W Solar Panels
1 Set 1.5m cable with PV plug
1x 2 in 1 Connector
1 Set 3m cable with crocodile clamp
1 x 20A controller
Packing listing
1x100W Solar Panels
1x1000W inverter (12V to 110V / 12V to 220V)
1 Set 1.5m cable with PV plug
1 Set 3m cable with crocodile clamp
1 x 10A controller
Packing listing
2x100W Solar Panels
1x1000W inverter (12V to 110V / 12V to 220V)
1 Set 1.5m cable with PV plug
1 Set 3m cable with crocodile clamp
1 x 20A controller
1x 2 in 1 Connector
100W Solar Panel Product specifications
Maximum power(Pmax) 100W
Maximum system voltage 600V DC
Open circuit voltage(Voc) 19.8V
Short circuit current(Isc) 6.66A
Maximum power voltage(Vmp) 16.5V
Maximum power current(Imp) 6.06A
Number of cells 30pcs
Weight 2KG
Size 975mm*550mm*3mm
Operating temperature(NOCT) 45 plus or minus 2 Celsius system
STC: lrradiance1000w/m2,Temperature 25 Celsius system, AM=1.5
Please note that the solar panel power output refers to the test output at STC: lrradiance1000w/m2,Temperature 30 Celsius system, AM=1.5
The output power of other tests in different environments will be different. In addition, the solar panel needs to be in the sun to have output. If you want to test, you need to test it in the sun
Product Description
Made of monocrystalline silicon substrate from a single large crystal.
Semi-flexible solar panel is the alternative solar module - lighter, thinner. It charges your on-board 12V battery of your motorhome, caravan, boat or other vehicle automatically, silently and maintenance free. ,is much more flexible than comparable solar modules. Curved surfaces such as boat decks or caravan alcoves are easily mounted junction box, for additional protection.
Boats/Sailboats, Yachts, Marine applications
Motorhomes/RVs, Expedition Vehicles, Commercial Trucks/Trailers, Caravans/Popup Off-Grid and Remote Communication places
Precautions
This product we set up inventory in Russia, Canada, Ukraine, Australia,Spain,Belgium. When you buy it, we will ship from your country that you don't need to consider customs clearance and duties and it will be fast delivery.
However,the zip code in Spain that starts with 35, 38, 51, 52 need to provide buyer identity information, sales vouchers, and add 15 euros for customs clearance and duties.
The zip code in Russia that starts with 6,the delivery time is long ,maybe 30-45 days and some zip codes will only be sent to the post office instead of the shipping address,you need to go to the post office to pick up the parcel.
Some areas of Canada are remote areas and need to add remote fees. When you need to add remote fees, we will send you an email. Please check the mail, thank you!
Connection 1.Connect the battery to the charge regulator - plus and minus. 2.Connect the photovoltaic module to the regulator - plus and minus . 3. Connect the consumer to the charge regulator - plus and minus. The reverse order applies when deinstalling! An improper sequence order can damage the controller!
Solar photovoltaic system manual
Important safety instructions
This manual contains the safe installation and operation instructions of solar modules and solar controller (hereinafter referred to as "controller").
Please read all instructions and precautions in each product manual and manual carefully before installation and use.
1 Solar module products
a. This product must not be in contact with highly corrosive substances to avoid excessive bending and long-term bending;
b. The solar panel should be prevented from stacking and falling down, the solar flexible panel cannot be disassembled, do not collide with hard objects, avoid trampling, and avoid scratching the surface with hard objects during use;
c. A large number of scratches or dirt on the surface of the solar panel may result in low efficiency of the solar panel, which may seriously cause burnout;
d. The suitable ambient temperature range of solar panels: -20 ℃-80 ℃, do not exceed this range;
e. The solar panel must be installed in an area with good sunlight and no shadow. The solar panel may work in the shaded sunlight for a long time and there may be a risk of burnout;
f. When used in series connection, the "+" of the previous component is connected to the "-" of the next component. The same panel cannot be directly connected to the positive and negative poles.
2 Solar panel connection installation method
When you use a 12V battery, use a parallel connection; when you use a 24V battery, use two serial connections. Please install the solar panel on a smooth surface with good sunlight and no shadow, and try not to install it on uneven areas. Solar panels can be fixed with glue or bolts.
5 Causes and solutions of solar panel failure
a. The output power of the solar panel is low: ① Check the panel surface for damage. ②Ensure that the photovoltaic panel is under a strong light intensity. The test conditions of the parameters given in the manual are the standard test conditions, illumination intensity 1000W/m2, Temperature 25℃, AM=1.5. Therefore, in the case of insufficient light, it may be The result is that the output power of the solar panel is low. ③ Both the controller and the inverter will have loss efficiency. ④ Please ensure that the surface of the photovoltaic panel is not blocked by any shadows or objects, which is also the reason for the low output power of the photovoltaic panel.
b. There is no voltage and current output of the solar panel: ① Adjust the multimeter to the correct gear to ensure the conditions of light and unobstructed; ② Check whether there is any loose joints and whether the panel is damaged. ③ In the case that there is no problem in the above two points, please remove the cover of the junction box of the solar panel, cut off the diode in the junction box, and then test whether the voltage and current are normal to detect whether the diode is damaged.
c. The solar panel is severely heated or has obvious melting or burning spots: due to improper handling, the solar cells inside the solar panel are broken, or the power is generated under the condition of a small shadow for a long time, which may cause the solar panel to heat or burn.